CX-9500PRO Argon-Purged Benchtop Direct Reading Spectrometer
1. High integration, high reliability and high stability
The CX-9500PRO Full-Spectrum Direct Reading Analyzer is fast and fast, measuring the elemental composition of all channels in less than 20 seconds. For different analytical materials, by setting the pre-ignition time and marking, the instrument can achieve the best analysis effect in a short time.
2. Special light chamber structure design
The volume of the optical chamber is smaller, and the argon filling speed is less than half of that of ordinary spectrometers; The optical system adopts an argon filled constant temperature optical chamber, and the arc flame generated during excitation is directly introduced into the optical chamber by the lens to achieve direct optical path passing, eliminate optical path loss, improve the detection limit, accurate measurement results, good reproducibility and long-term stability.
1. Automatic optical path calibration
The optical system automatically performs spectral line scanning to ensure the correctness of reception and eliminate tedious peak scanning work. The instrument automatically identifies specific spectral lines, compares them with the original storage lines, determines the drift position, and finds the current pixel position of the analysis line for measurement.
4. All core components are imported originally
HEPS digital solid-state light source, adaptable to a variety of different materials; Copper spark table base to improve heat dissipation and sturdy performance; The tungsten electrode is used to make the electrode last longer, and the electrode self-purge function is designed to make it easier to clean the electrode.
5. Special open electrode frame design
Adjustable sample holders facilitate analysis of samples of various shapes and sizes.
6. High-performance DSP and ARM processor
It has the function of high-speed data acquisition and control, and automatically monitors the operating status of the optical chamber temperature, argon pressure, light source, excitation chamber and other modules in real time.
7. Anti-pollution device
Solid-state adsorption trap prevents oil and gas from polluting the optical chamber and improves long-term operation stability.
8. Air circuit design
Ethernet connection is used between the instrument and the computer, which has good anti-interference performance, and the external computer upgrade has nothing to do with the instrument configuration, so that the instrument has better applicability; The reasonable argon gas path design shortens the argon flushing time when the sample is excited, saving argon for users; There is no cost to change and increase the channels within the matrix.
9. Comprehensive working curve
The working curve adopts international standard samples, pre-made working curves, which can be extended and expanded according to needs, and each curve is excitation generated by up to dozens of standard samples, and the interference is automatically deducted.